TRITON 8100, 9100, 9700 BALANCING
PROCEDURES
These procedures are intended for Triton 9700 model
operating with software version ZD990003.16 or higher. The software version can
be verified by logging on to the Customer Transaction Management Function screen.
On the bottom of the screen you will find the “LOAD” version number. If you
have an earlier version you will need to use the previous balancing procedures.
- Log
onto “MANAGEMENT FUNCTIONS” by first pressing the control key then
the “1” on the keypad.
- Select
“MANAGEMENT FUNCTIONS”.
- Enter
your management code using the keypad, and then press ENTER.
- Select
“CLOSE”.
- Select
“CASSETTE CLOSE”.
- Select
“A”.
- Select
“TRIAL CASSETE CLOSE”.
- (The
ATM will print out a receipt showing your starting and remaining amount).
- Select
“CASSETTE CLOSE”.
- Select
“A”
- Select
“CLOSE”
- Select
“ENTER QUANITY IN CASSETTE”. You may have to navigate from the
Management functions screen. (See #2 above)
- Enter
the number of bills that are currently in the cassette.
- From
the “CASSETTE A” screen. Select “TRIAL CASSETE CLOSE”.
- (The
ATM will print out a receipt showing your starting and remaining amount).
- Select
“EXIT”.
- Select
“CUSTOMER TRANSACTIONS”.
- (ATM
will reset and come back into service)
CLEARING ATM JOURNAL
- Press
the Control Key and the Number 1 key at the same time.
- Select
“MANAGEMENT FUNCTIONS”.
- Enter
your management code using the keypad, and then press “OK”.
- Select
“JOURNAL”.
- Select
“PRINT JOURNAL”. Journal will print – Save the journal for one year.
- Select
“CLEAR JOURNAL”.
- Select
“YES”.
- Select
“EXIT”.
- Select
“EXIT”.
- Select
“CUSTOMER TRANASACTIONS” and
ATM will reset and come back into service.
To recover from error code 156:
- Turn
off and turn ATM back on.
- Select
“MANAGEMENT FUNCTIONS”.
- Enter
your management code using the keypad, and then press OK.
- Select
“CASSETTE SERVICE”
- Select
“A”
- Select
“EXIT”.
- Select
“EXIT”.
- Select
“RESET ERROR”
- Select “CUSTOMER TRANSACTIONS”